Module 1: Abend Codes
S806- Load Module Not Found
S806 abends the step when the system cannot find the program load module in the library search order.
What it means
- The step was never executed because the program named on the EXEC statement could not be located in any library.
- S806 is a load/attach problem, not a logic bug in your program - the program never got control.
Common causes
- Misspelled program name in the PGM parameter of the EXEC statement.
- The program was compiled but never link-edited, so no load module exists in the load library.
- The STEPLIB or JOBLIB DD points to the wrong library or the wrong dataset name.
- The load module sits in a private library that is not in the search order of this step.
How to find it
- Look for the IEF212I message in the job log - it names the module that could not be found.
- Check the reason code on S806 (reason 04 means module not found in LPA, JPA, STEPLIB, JOBLIB or linklist).
- Compare the PGM name letter by letter with the member name in the load library.
How to fix it
- Verify the spelling of the program name on the EXEC PGM= parameter.
- Check that the STEPLIB (or JOBLIB) DD points to the load library that really holds the module.
- Confirm the linkedit step ran successfully and created the load module.
Example
- A step telling the system where the load module lives:-
//S806JOB JOB (ACCT),'LOAD MODULE TEST',CLASS=A,MSGCLASS=X //STEP1 EXEC PGM=MYPROG //STEPLIB DD DSN=MY.LOADLIB,DISP=SHR //SYSOUT DD SYSOUT=*
- If MYPROG is not a member of MY.LOADLIB, this step abends with S806 and IEF212I names MYPROG.